Difference between revisions of "Wire Recommendations"

From PTI Security Systems
Jump to: navigation, search
(Created page with "We have a list of the recommended wire types for installing PTI manufactured products as well as many of the other access control and security products that we sell to complim...")
 
Line 13: Line 13:
 
</ul>
 
</ul>
  
If you would like to purchase any of the wire recommended below, please contact our Sales Department representatives by telephone at (800) 331-6224, by email at [mailto:sales@ptisecurity.com sales@ptisecurity.com], or by using our [https://store.ptisecurity.com Web Store].
+
If you would like to purchase any of the wire recommended below that has a PTI part number, please contact our Sales Department representatives by telephone at (800) 331-6224, by email at [mailto:sales@ptisecurity.com sales@ptisecurity.com], or by using our [https://store.ptisecurity.com Web Store]. Items without part numbers are not available for purchase through PTI, but are noted so that other sources may be located.
 +
 
 +
{| class="wikitable" style="color: green;"
 +
! Description
 +
! PTI Part #
 +
! Belden Wire Code
 +
! Ohms Per Foot Resistance
 +
|-
 +
|18 awg, 4 conducter stranded copper wire with overall shield and common ground (PVC insulation).
 +
|WWIR1804S
 +
|9418
 +
|6.92
 +
|-
 +
|18 awg, 4 conducter stranded copper wire with overall shield and common ground (Plenum insulation).
 +
|
 +
|89418
 +
|6.92
 +
|-
 +
|18 awg, 4 conducter stranded copper wire with overall shield and common ground (Direct Burial).
 +
|WWIR1804SDB
 +
|9552
 +
|6.92
 +
|}

Revision as of 16:28, 18 September 2014

We have a list of the recommended wire types for installing PTI manufactured products as well as many of the other access control and security products that we sell to compliment our system.

  • Always refer to local code prior to ordering the wire for your site, as these requirements may be more stringent.
  • We strongly recommend that you purchase the wire for your system from PTI as we have determined the most ideal wire over years of experience and testing.
  • Using the incorrect wire for an application can cause many problems with voltage drop, RF Interference, and ground faults; resulting in lost revenue and greatly increased costs for service, reinstallation, repair, and technical support.
  • Planning and installing the wiring of a site is a process that requires a high degree of technical knowledge; PTI recommends that this be done by a trained professional.
  • If you have questions, please contact our Technical Support Department.

If you would like to purchase any of the wire recommended below that has a PTI part number, please contact our Sales Department representatives by telephone at (800) 331-6224, by email at sales@ptisecurity.com, or by using our Web Store. Items without part numbers are not available for purchase through PTI, but are noted so that other sources may be located.

Description PTI Part # Belden Wire Code Ohms Per Foot Resistance
18 awg, 4 conducter stranded copper wire with overall shield and common ground (PVC insulation). WWIR1804S 9418 6.92
18 awg, 4 conducter stranded copper wire with overall shield and common ground (Plenum insulation). 89418 6.92
18 awg, 4 conducter stranded copper wire with overall shield and common ground (Direct Burial). WWIR1804SDB 9552 6.92